S351 Universal Timer Relay
Timing Function with Timing Function with
Control Functions
latching trigger momentary trigger
Commutating Relay
Bell cut off timer Reset pulse
Setup
Setup Setup
The function control terminals C and D
The function control terminals, D is The function control terminals, C is
are not connected. The Relay control
connected to +ve and C is not connected to +ve and D is not
jumper is in position R0 and the timing
connected. The relay control jumper is connected. The relay control jumper is
range T1 and T2 are not connected
in position R1. in position R1.
and have no function. The POT has no
Timing ranges Timing ranges
function.
Without a link in T1 and T2 is the lower Without a link in T1 and T2 is the lower
Operation
range from less than 1 second up to 60 range from less than 1 second up to 60
Apply a trigger. The relay changes over
seconds. When T1 and T2 are linked, seconds. When T1 and T2 are linked,
and the green led indicates. This will
this is the upper range from less than 1 this is the upper range from less than 1
remain until the first trigger is removed
minute up to 60 minutes. minute up to 60 minutes.
and a second trigger is applied, then
Operation Operation
the relay will switch back and the red
Apply a trigger, the green led Apply a trigger, the green led
led will indicate, until the trigger is
illuminates, but the relay doesn’t illuminates, but the relay doesn’t
removed when the led will extinguish.
switch. If the trigger is removed, the led switch. If the trigger is removed, the
extinguishes and the timing is stopped. timing continues. When the time
A-stabling Relay
If the time period expires while the period expires with the trigger
Setup
trigger is still applied, then the relay removed, then the relay switches and
The function control terminals C and D
switches and the red led illuminates. the red led illuminates. This will remain
are both connected to +ve. The Relay
This will remain until the trigger is for 1 second, then the relay will switch
control jumper is in position R0 and
removed. back and the led extinguish.
has no function.
Rate of A-stable.
Max time switch Pulse stretching
Without a link in T1 and T2 is the lower
Setup Setup
range from less than 1 second up to 10
The function control terminals, D is The function control terminals, C is
seconds. When T1 and T2 are linked,
connected to +ve and C is not connected to +ve and D is not
this is the upper range from 3 to 60
connected. The relay control jumper is connected. The relay control jumper is
seconds.
in position R0. in position R0.
Operation
Timing ranges as above. Timing ranges as above.
Apply a trigger and the relay will a-
Operation Operation
stable. When the relay is switched the
Apply a trigger, the green led Apply a trigger, the green led
green led illuminates and when the
illuminates, and the relay switches. If illuminates, and the relay switches. If
relay is un-switched, the red led
the trigg er is remo ved, the led the trigger is removed, the timing
illuminates. When the trigger is
extinguishes, the relay switches back continues. When the time period
removed, the relay will stop a-stabling,
and the timing is stopped. If the time expires with the trigger removed, the
reset to the un-switched state and the
period expires while the trigger is still relay switches back and the red led
led will extinguish.
applied, then the relay switches back illuminates for 1 second and then
and the red led illuminates. This will extinguishes.
remain until the trigger is removed.
The trigger terminals, A is a -ve applied to trigger, B is +ve applied to trigger.
Note
This unit requires 12v dc to power it at all times. (10-14v dc).
If the input is not removed when the timing has finished in both
momentary trigger modes, then the led will remain illuminated red
and the relay will remain in the state that it was when the led
illuminated red until the trigger is removed.
Contact ratings
The relay is DPCO rated 1Amp @ 12v dc. It must not be used to
switch mains voltages.
60135 Iss 1 Sept 11
T. 01744 886600 F. 01744 886607 E. [email protected] W. www.hoyles.com
Hoyles Electronic Developments Ltd
12V DC
-VE TRIGGER
Function
Controls
Timing
Range
+VE TRIGGER
Relay
Control
LED1
LED2
NC
+
A
D
B
C
-
RELAY1
021-105 iss2
RELAY2
NCNO NO
MIN MAX
COM COM
T1
T2
J1
R0
R1
Boxed Version. If you have the boxed version of the S351, the decal
(included) has a clear window 10mm x 46mm. The area under the
decal is 12mm wide to take standard labelling machine tape. The
window is free from adhesive, nevertheless, it is wise to maintain
cleanliness and avoid fingerprints on the inside of the window. If a
labelling machine is not available a paper label can be used. For a
small extra charge these products can be factory labelled to your
requirements (subject to a character limit).
Vista de pagina 0
1

Indice de contenidos

Pagina 1 - S351 Universal Timer Relay

S351 Universal Timer RelayTiming Function with Timing Function with Control Functionslatching trigger momentary triggerCommutating RelayBell cut off

Comentarios a estos manuales

Sin comentarios

Benefon Telefony komórkowe podręczniki użytkownika

Zaczynanie od D

Kliknij na poniższy alfabet, aby przejść do pełnej listy modeli zaczynających się od tej litery

Modele Rodzaj dokumentu
DELTA TDP-40-TN2
Instrukcja Obsługi   Benefon DELTA TDP-40-TN2 Service manual, 208 strony